For years our company is always devoted to provide the best CFI-I study materials to the clients and help them pass the test CFI-I certification smoothly. Our company tried its best to recruit the famous industry experts domestically and dedicated excellent personnel to compile the CFI-I Study Materials and serve for our clients wholeheartedly. Our company sets up the service tenet that customers are our gods and the strict standards for the quality of our CFI-I study materials and the employee’s working abilities and attitudes toward work.

NFPA CFI-I Exam Syllabus Topics:

TopicDetails
Topic 1
  • Fire Protection Systems & Equipment: This section evaluates the skills of Fire Safety Technicians and focuses on determining the operational readiness of fire suppression systems, alarm systems, and portable fire extinguishers.
Topic 2
  • Administration: This section of the exam measures the skills of Fire Inspectors and covers the preparation of inspection reports, identifying the need for permits, and recognizing when plan reviews are required. It also involves investigating complaints, identifying applicable codes, and participating in legal proceedings. One key skill measured is communicating findings clearly in written reports.
Topic 3
  • Occupancy Types: This section tests the abilities of exam-takers to assess fire and life safety systems for different occupancy types, including assembly, educational, and healthcare facilities.
Topic 4
  • Storage, Handling, & Use of Hazardous Substances and Materials: This module measures the skills of Fire Inspectors and includes recognizing hazardous conditions in equipment, processes, and operations.

>> Reliable CFI-I Study Notes <<

CFI-I Latest Test Answers & CFI-I Top Questions

In today's technological world, more and more students are taking the Certified Fire Inspector I (CFI-1) (CFI-I) exam online. While this can be a convenient way to take a Certified Fire Inspector I (CFI-1) (CFI-I) exam dumps, it can also be stressful. Luckily, VCEEngine's best NFPA CFI-I exam questions can help you prepare for your NFPA CFI-I Certification Exam and reduce your stress. If you are preparing for the Certified Fire Inspector I (CFI-1) (CFI-I) exam dumps our CFI-I Questions help you to get high scores in your Certified Fire Inspector I (CFI-1) (CFI-I) exam.

NFPA Certified Fire Inspector I (CFI-1) Sample Questions (Q49-Q54):

NEW QUESTION # 49
During an inspection, it is determined that the installation of a new suppression system is significantly different from the one approved during plans review. What action should be taken by the inspector?

  • A. Indicate the modifications on the approved plan
  • B. Evaluate the installation for compliance
  • C. Issue a violation notice to the owner
  • D. Require a submittal of a set of corrected plans

Answer: D

Explanation:
When a significant deviation from the approved plans is discovered during an inspection, the appropriate action is to require a submittal of a set of corrected plans. This is necessary to ensure the system is reviewed and approved in compliance with the applicable codes and standards.
Issue a violation notice (A): While this may be a secondary step if the system does not meet code, it is not the first step when encountering unapproved changes.
Evaluate the installation for compliance (B): Inspectors cannot simply evaluate the installation without updated plans, as the plans serve as the approved baseline for design compliance.
Require corrected plans (C): This step ensures that the new design is documented, reviewed, and approved before proceeding. It maintains compliance with NFPA standards.
Indicate modifications on the approved plan (D): Altering plans without proper review is not acceptable and does not ensure the system meets the original intent.
Reference:
NFPA 1 and NFPA 13: Systems must comply with approved designs and significant changes require resubmittal for review.


NEW QUESTION # 50
How often should manual fire alarm boxes be visually inspected?

  • A. Semiannually
  • B. Weekly
  • C. Annually
  • D. Monthly

Answer: D

Explanation:
Visual inspections for fire alarm system components are outlined in NFPA 72, National Fire Alarm and Signaling Code, Table 14.3.1.
Monthly (B): Manual fire alarm boxes must be visually inspected monthly to ensure they are free from obstructions and visible to occupants.
Weekly (A): Weekly inspections are not required for manual pull stations.
Semiannually (C) and Annually (D): These intervals apply to other maintenance tasks, such as functional testing, not visual inspections.
Reference:
NFPA 72, Table 14.3.1: Inspection intervals for manual fire alarm boxes.


NEW QUESTION # 51
The NFPA Standard for the installation of stationary pumps for fire protection is:

  • A. NFPA 25
  • B. NFPA 24
  • C. NFPA 20
  • D. NFPA 13

Answer: C

Explanation:
The standard for the installation of stationary fire pumps is specified in NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection.
NFPA 13 (A): Focuses on sprinkler system design and installation.
NFPA 20 (B): Covers the requirements for stationary pumps used in fire protection systems, including installation, performance, and acceptance testing.
NFPA 24 (C): Regulates private fire service mains and their appurtenances.
NFPA 25 (D): Outlines inspection, testing, and maintenance for water-based fire protection systems.
Reference:
NFPA 20, Chapter 4: Requirements for stationary fire pumps.


NEW QUESTION # 52
Egress capacity for stairs in high-hazard content areas is based on how many inches (millimeters) per person?

  • A. 0.3 in. (8 mm)
  • B. 0.4 in. (10 mm)
  • C. 0.2 in. (5 mm)
  • D. 0.7 in. (18 mm)

Answer: B

Explanation:
Egress capacity requirements are detailed in NFPA 101, Life Safety Code, Section 7.3.3.1. For stairs in high-hazard content areas, the capacity is based on:
0.4 in. (10 mm) per person (C): This measurement ensures adequate space for occupants to evacuate safely, considering the increased risk associated with high-hazard contents.
Lower values, such as 0.2 in. (A) or 0.3 in. (B), are insufficient for high-hazard areas.
0.7 in. (D): This exceeds the required value for stairs in high-hazard occupancies.
Reference:
NFPA 101, Section 7.3.3.1: Egress capacity requirements based on occupancy and hazard levels.


NEW QUESTION # 53
Which of the following is not the responsibility of the installing contractor when pursuing approval of sprinkler systems and private fire service mains?

  • A. Notify the AHJ of the time and date testing will be performed
  • B. Perform all required acceptance tests
  • C. Perform annual tests on all existing systems
  • D. Complete and sign the appropriate contractor's materials and test certificates

Answer: C

Explanation:
Responsibilities of the installing contractor for sprinkler systems and private fire service mains are specified in NFPA 13, Standard for the Installation of Sprinkler Systems:
Notify the AHJ (A): The contractor must inform the AHJ about the date and time of acceptance tests.
Perform all required acceptance tests (B): Contractors are responsible for conducting these tests to ensure the system meets NFPA standards.
Complete and sign test certificates (D): The contractor must certify the materials and tests by completing and signing the appropriate documents.
Perform annual tests on all existing systems (C): This is not the contractor's responsibility. Annual testing and maintenance are typically handled by the building owner or their representative under NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems.
Reference:
NFPA 13, Chapter 24: Responsibilities of the installing contractor.
NFPA 25: Maintenance and testing responsibilities for existing systems.


NEW QUESTION # 54
......

Time and tide wait for no man, if you want to save time, please try to use our CFI-I preparation exam, it will cherish every minute of you and it will help you to create your life value. With the high pass rate of our CFI-I exam questions as 98% to 100% which is unbeatable in the market, we are proud to say that we have helped tens of thousands of our customers achieve their dreams and got their CFI-I certifications. Join us and you will be one of them.